El producto satisface las necesidades del servicio t
;
This is a good quality scan of the Operation & Maintenance (Service) Manual for the PAL version of this high-band broadcast umatic, BVU-800P
All schematics and lineup procedures appear to be included in this one manual AFAICT.
The file size is just over 113 MB which gives an idea of the quality and number of pages.
All of the schematics, which contain some fairly small print, are easily readable when you zoom into the page.
John Thompson, Newcastle Upon Tyne, England.
;
Good quality, all schematics of few of models. There is also short form of user manual and regulation manual.
;
Perfect copy of the service manual. you can enlarge every page, and it comes up
with all details.
;
It´s very very nice manual with all, what i need. Original in good quality. Very fast business. Very much thanks...
LIST OF CAUTION, NOTES, AND SYMBOLS USED IN THE SCHEMATIC DIAGRAMS ON THE FOLLOWING PAGES:
1. CAUTION: FOR CONTINUED PROTECTION AGAINST RISK OF FIRE, REPLACE ONLY WITH SAME TYPE_A,_V FUSE. ATTENTION: UTILISER UN FUSIBLE DE RECHANGE DE M�ME TYPE DE_A,_V. 2. CAUTION: Fixed Voltage (or Auto voltage selectable) power supply circuit is used in this unit. If Main Fuse (F601) is blown, first check to see that all components in the power supply circuit are not defective before you connect the AC plug to the AC power supply. Otherwise it may cause some components in the power supply circuit to fail. 3. Note: (1) Do not use the part number shown on the drawings for ordering. The correct part number is shown in the parts list, and may be slightly different or amended since the drawings were prepared. (2) To maintain original function and reliability of repaired units, use only original replacement parts which are listed with their part numbers in the parts list section of the service manual. 4. Wire Connectors (1) Prefix symbol "CN" means "connector" (can disconnect and reconnect). (2) Prefix symbol "CL" means "wire-solder holes of the PCB" (wire is soldered directly). 5. Voltage indications on the schematics are as shown below: Plug the TV power cord into a standard AC outlet.:
1 5.0 (3.0) Voltage
2
3 5.0 (3.0) Power on mode Power off mode Unit: Volts
Indicates that the voltage is not consistent here.
6. How to read converged lines
1-D3 Distinction Area Line Number (1 to 3 digits) Examples: 1. "1-D3" means that line number "1" goes to the line number "1" of the area "D3". 2. "1-B1" means that line number "1" goes to the line number "1" of the area "B1".
7. Test Point Information
3 AREA D3 2 1 A
1-B1 AREA B1 1-D3 B C D
: Indicates a test point with a jumper wire across a hole in the PCB. : Used to indicate a test point with a component lead on foil side. : Used to indicate a test point with no test pin. : Used to indicate a test point with a test pin.
2-2